Recently, as various damages are expected due to the risk of falling space debris, many studies are being carried out to acquire space object information. In this research, an optical-based space object surveillance system was developed toacquire information about space objects. To acquire orbit information by photographing a space object with this system, the accuracy of position data of the space object is important. The telescope coordinate is located in the 2D CCD plane of the telescope, and the space objects are in the celestial coordinate. The two coordinates have a non-linear relation caused by a deflection of the mechanical system, a scattering of the atmosphere and so on. In this study, we propose an alignment method for two coordinate systems. First, a model that analyzes the geometric relation between the telescope system on earth and space objects is explained. Then, we also propose a second model with the addition of correction parameters. As a result of performing coordinate alignment according to the method and procedure proposed in this study, the pointing accuracy is lowered below 3 arcsec.
영어초록
Recently, as various damages are expected due to the risk of falling space debris, many studies are being carried out to acquire space object information. In this research, an optical-based space object surveillance system was developed toacquire information about space objects. To acquire orbit information by photographing a space object with this system, the accuracy of position data of the space object is important. The telescope coordinate is located in the 2D CCD plane of the telescope, and the space objects are in the celestial coordinate. The two coordinates have a non-linear relation caused by a deflection of the mechanical system, a scattering of the atmosphere and so on. In this study, we propose an alignment method for two coordinate systems. First, a model that analyzes the geometric relation between the telescope system on earth and space objects is explained. Then, we also propose a second model with the addition of correction parameters. As a result of performing coordinate alignment according to the method and procedure proposed in this study, the pointing accuracy is lowered below 3 arcsec.
자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다. 자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다. 저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
파일오류
중복자료
저작권 없음
설명과 실제 내용 불일치
파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우